CZPT Pulse Vacuum Steam Sterilizer Autoclave (Wg Collection)
The function and the use
The cabinet utilize the bodily qualities of the saturated steam, which would launch large quantities of latent heat and humidity throughout condensation, and with a period of time to preserve the objects at higher temperature and moist problem, the principal protein of the microorganisms would be solidified so that the micro organism can be killed.
The devices is widely utilised in pharmaceutical, health care, scientific and other industries for the substantial temperature sterilization, cooling and drying process to the biological products, health-related devices, sterile garments, tools, utensils, healthcare and the objects.
Main parameter
Model | Potential | Inner Chamber Dimension(L*W*H) | Outer Dimension(L*W*H) | Steam Strain and the Use | H2o Source Pressure and the Consumption | Energy | Internet Fat | Design Stress | Design and style Temperature |
WG-.25JS(D) | .25m³ | 800*600*600mm | 1100*1300*1700mm | .four-.8Mpa 15KG | .15-.3Mpa 35KG | 2+24KW | 900KG | .25 Mpa |
139 ºC |
WG-.36JS(D) | .36m³ | 1000*600*600mm | 1300*1300*1700mm | .4-.8Mpa 20KG | .15-.3Mpa 40KG | 2+24KW | 1000KG | ||
WG-.6JS(D) | .6m³ | 1200*610*910mm | 1500*1350*1950mm | .four-.8Mpa 30KG | .fifteen-.3Mpa 45KG | 3+36KW | 1400KG | ||
WG-.8JS(D) | .8m³ | 1500*610*910mm | 1800*1350*1950mm | .four-.8Mpa 40KG | .15-.3Mpa 50KG | 3KW | 1600KG | ||
WG-1.2JS(D) | 1.2m³ | 1500*680*1180mm | 1790*1450*1950mm | .four-.8Mpa 48KG | .fifteen-.3Mpa 55KG | 4KW | 1800KG | ||
WG-1.5JS(D) | one.5m³ | 1900*680*1180mm | 2190*1450*1950mm | .four-.8Mpa 55KG | .fifteen-.3Mpa 60KG | 4KW | 2000KG | ||
WG-2.0JS(D) | two.0m³ | 1700*1000*1200mm | 2000*1850*2000mm | .four-.8Mpa 65KG | .fifteen-.3Mpa 65KG | 4.5KW | 2500KG |
The traits
1. The main human body is with horizontal rectangle double layer structure, the inside of chamber is made of
SUS31608 or SUS30408 stainless metal, the outer layer is produced of the brushed decorative sheet, and the there is motorized door or sliding door for pick, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD necessary.
two. The management technique: Adopt the Siemens PLC and Siemens touch display.
3. The piping system:
Undertake with the reliable Germany Burkert or GEMU pneumatic angle kind valve, drinking water ring vacuum pump and .22um large effectiveness sterile health care quality filters, the pipe clamp adopts the quick connectors, the piping and the associated spares are all in accordance to the sanitation CZPT.
The Attributes for the Computer software
1, With Genmany Simens PLC platform impartial study and advancement, human-CZPT Conversation, hassle-free for procedure.
two, Application style and manufacture goods in strict accordance with the specialized needs for the sterilization process.
three, The Functioning authority is divided into 3 stages to the supervisor, the technologist, and the operators.
four, Software interlocked, by the system is managing, the sealing door can not be open up.
5, All the alarm and the technological figures can be recorded and print.
six, If the interior chamber is greater than the protection pressure, the doorway can not be open.
7, Excellent solution protection safety measures, four amount crisis therapy of abnormal condition.
Sterilizing Cycles:
The sterilization cycle to the sound objects:
Utilized to the devices, dressings, utensils and other objects.